Effect of the Different Buffer on Electrophoretic Mobility Shift Assay (EMSA)

ZHENG Hai-xia, WANG Yu-guo, FENG Zhi-fu   

  1. College of Agronomy, Shanxi Agricultural University, Taigu 030801, China
  • Received:2009-06-10 Published:2009-12-28

Abstract: The test of Electrophoretic Mobility Shift Assay is very simple in theory.But to successfully carry out gel shift experiments,it needs to optimize the parameters.Through a combination of T7 RNA polymerase and T7 Promoter for testing proper buffer was selected.The experimental results showed 5 × binding-Buffer 1 was more suitable for the test;TBE running2buffer was better than TAE and TGE buffer;0.× TBE buffer was the best concentration amang there electrophoresis buffer.

Key words: EMSA, Buffer, Optimize